SNMP CARD MODULE FOR ARMAC UPS

195,99 €

Monthly payment starting from 6,68 €

Open installments calculator

Photopoint hire purchase calculator

Please add some items to your shopping cart and choose "hire purchase" for the payment type

Main info

SNMP card for UPS - extension for Armac uninterruptible power supplies

The SNMP network card is a communication accessory that extends the capabilities of compatible Armac-Energy UPS units with full real-time management and monitoring from anywhere via a web browser and SNMP manager. With integrated network access, users can schedule UPS shutdowns, startups, or restarts, view basic battery status and key parameters—all without installing additional software. The solution supports event logs, self-test schedules, email notifications, SNMP traps, and custom alarm limits, providing centralized control over the entire emergency power system.

Modbus 485 Poll/Slave & Modbus TCP/IP:
industrial-grade connectivity

Modbus RTU (485): the card can operate as Poll (master), where in this mode it allows querying up to 8 external sensors/devices, or as Slave, providing UPS parameters, e.g., to PLC controllers. The modes are switchable and mutually exclusive.

Flexible configuration: regardless of the mode, the user defines the bandwidth, parity, device address number, functions, and in Poll mode, specifies the exact register from which the card is to retrieve data.

Modbus TCP/IP protocol: encapsulates RTU frames in Ethernet packets (port 502, which can be changed), enabling remote access to UPS parameters using this protocol where a physical connection is not directly possible. Thanks to this implementation, there is no need to run a cable to connect end devices using Modbus TCP/IP or those that require a physical port using a TCP/IP to RTU converter.

SNMPv1 / SNMPv2c / SNMPv3 basic:
network management of multiple UPS units

The card's SNMP agent supports UPS-MIB (RFC1628) and its own implementation of the so-called private enterprise (PPC), which allows for extensive control of various parameters not only of the UPS itself, but also of environmental sensors (EMD) connected by the card user. SNMP TRAP enables automatic (passive) alarm notification in versions 1 and v2c, and a ready-made simple UPS control set on the website provides simple control commands (10 s test, bypass on/off, buzzer off). The basic version of v3 provides login and password authentication.

Importantly, each Armac emergency power supply system is equipped with an overload protection module. When the UPS is overloaded during normal operation, the device will automatically and safely shut down the power supply to the equipment connected to it. This solution enhances the safety and comfort of using Armac emergency power supplies.

Compliance with RFC 1628 UPS-MIB

The RFC1628 standard defines a uniform, standardized set of objects (known as OIDs) — from UPS statuses, operating parameter values, and batteries to alarms and tests — for each UPS. The Armac card supports all important OIDs of this RFC and extends the default resolution of this MIB data representation by providing values with a decimal part (mV, 0.1 Hz, 0.01 °C), which facilitates precise load and temperature monitoring without the need for PPC-type implementations.

SMTP with SSL, NTP, and DNS: secure notifications
  • MTP (TLS/SSL, STARTTLS): sending alerts to multiple email accounts (with authorization).
  • NTP: automatic clock synchronization, ensuring that SNMP and CSV logs have consistent timestamps from devices within a given organization or system.
  • DNS: host name resolution.
Other technologies and functionalities

Wake On LAN – the ability to remotely turn on a server/PC (if they support this feature) after power is restored or the UPS returns from battery operation.

Task schedule – periodic UPS* switching on/off, battery tests, calibrations.

Configurable alarm thresholds for voltage, temperature, humidity, and battery life.

Remote code execution allowing control of any device using SSH or Telnet. No additional software is required to, for example, shut down a server or execute a user-defined script. With this function, dedicated commands are executed by the SNMP card for each type of event.

Event and parameter logging with CSV export option via a permanent link. Here, it is necessary to add that events (e.g., exceeding the alarm threshold defined by the user) and parameters, i.e., periodic recording of parameters on the UPS, are logged.

Easy firmware (FW) update via the web interface.

Why Armac-Energy?

We focus on reliability, open standards, and simple integration with existing IT and automation infrastructure. The SNMP card for Armac UPS is a compatible network M C (NMC) plug-in that allows remote control of the UPS and monitoring of critical data in a unified management environment, providing access to it through multiple interfaces. It is the ideal solution for installers, administrators, and end users who, in line with our mission of “Creating Good Energy,” want to combine power protection with intelligent analytics.

Dimensions and weights

Package width
7.5 cm
Package height
4.5 cm
Package length
8 cm

Product codes

EAN
5901969445305
Manufacturer code
SNMP/A/001

Photopoint offers free shipping for orders over 99 € delivered to Estonia. Take a look in the tab "Delivery" for a more precise delivery estimate.

For this product you can select the desired delivery method at the shopping cart:

Photopoint store Pick-up


Place your order from Photopoint web store and pick your goods up from one of Photopoint`s brick and mortar stores. The delivery to Photopoint store is free even for orders less than 99 €. You will be noticed by e-mail when your order is ready for pick-up.

The Photopoint stores are located in Tallinn and Tartu. See the exact locations from here.

Omniva parcel terminal 

You can order the goods to one of the Omniva Parcel terminals. Choose the desired terminal at the shopping cart. As the shipment arrives to the selected terminal, you will be sent an SMS-notification with an unique code. Go to the terminal within a week, enter the code and take your package. It is as simple as that.

See Omniva Parcel terminal locations here.

SmartPOST parcel terminal

Did not find an Omniva terminal at suitable location? Try SmartPost. Choose the desired terminal at the shopping cart. As the shipment arrives to the selected terminal, you will be sent an SMS-notification with an unique code. Go to the terminal within a week, enter the code and take your package. This method actually works for all parcel terminals.

See SmartPOST parcel terminal locations here.

DPD parcel locker

Make sure you check out also the locations of DPD parcel lockers. These are located all over Estonia. The delivery is the same. As the shipment arrives to the selected locker, you will be sent an SMS with a unique code. Go to the locker, enter the code and take your package.

See DPD parcel locker locations here.

Smartpost Finland parcel terminal

SmartPOST Finland is the best way to order goods to Finland. These terminals work the same way as in Estonia. As the shipment arrives to the selected terminal in Finland, you will be sent an SMS-notification with an unique code. Go to the terminal, enter the code and take your package.

See SmartPOST Finland parcel terminal locations here.

Matkahuolto parcel service

Matkahuolto is easy way to order goods to Finland. These are located also in smaller Finnish towns. As the shipment arrives to the selected Matkahuolto outlet, you will be sent an SMS-notification or an e-mail. Go to the outlet, show your ID and take your package.

See Matkahuolto outlet locations here.

Omniva courier delivery

The courier will transport your goods from Photopoint straight to the provided address. The delivery will take place at workdays from 08:00 to 17:00. Hold your phone near you as the courier will call you prior to its arrival. Please make sure there is someone at the destination, eligible to receive the shipment. 

The product can only be ordered from our online store and it takes from 7-10 working days for delivery within Estonia.

Product comparison

Close